ABSTRACT |
To test the efficacy of UVA-LED disinfection, a solution of Escherichia coli was pumped through a modified drip flow reactor at a flow rate of 1 ml/min. The experiment was conducted in a controlled environment chamber to ensure that temperature did not cause disinfection. The reactor featured three wells with different treatments: UVA-LED irradiation, UVA-LEDs with Ti02, and UVA-LEDs with nanosilver. Samples from each well were taken throughout a 340 hour period, inactivated, assayed, and analyzed for E. coli disinfection. Results of the duplicate experiments indicated longer exposure times are needed for UVA-LED disinfection of E. coli in water. Further research would consider a longer sampling period and different test conditions, such as increased contact area and various flow rates. |