    타이틀 Point-of-Load Converters: Space Qualification Issues
    저자 Leon, Rosa
    Keyword LINEAR QUADRATIC REGULATOR;; LOAD TESTS;; RELIABILITY;; SYNCHRONISM;; TRANSIENT RESPONSE;; VOLTAGE REGULATORS
    URL http://hdl.handle.net/2060/20100042142
    보고서번호 JPL-Publ-10-18
    발행년도 2010
    출처 NTRS (NASA Technical Report Server)
    ABSTRACT Tests were performed on space-qualified, point-of-load (POL) regulators to evaluate potential performance and reliability issues in their space use. For fiscal year (FY) 2010, two models of POL regulators were tested - a radiation-hard, low-drop-out linear regulator used in multiple flight applications, and a radiation-hardened, variable-output, synchronous buck regulator, which is intended for future flight applications. Some tests were performed at the thermal military extremes and below. Measurements performed include efficiency, regulation, load transient response, synchronization, and turn-on tests.