    제목(국문) 투과일사의 유입길이에 따른 Tilt 창호의 적정 기울기 산정
    제목(영문) The Calculation on the Optimum Angle of Tilt Type Window by Length of Transmitted Solar Radiation
    저자 조성우 (Sung-Woo Cho ,창원대학교 건축학부 ) ▷공저자네트워크등록하기
    초록 This study is suggested tilt window type to be restrained solar radiation through vertical window type in buildings. The shading and aesthetical effect of buildings would be solved by installation of tilt window type. For investigate optimum an angle of tilt window and building azimuth in reference region, the distance of transmitted solar radiation is calculated. The results of calculation showed optimum an angle of tilt window is obtained 7° that the distance of transmitted solar radiation is 20% of 1.5m of balcony width. In case of an tilt window angle of 7°, the optimum building azimuth is showed SW15°~SE15.
    keyword Tilt window(경사창호), Distance of transmitted solar radiation(투과일사길이), Azimuth(방위각), Angle of tilt window(경사창호의 기울기)
    저널명 설비공학 논문집 ▷관련저널보기
    VOL 22
    PAGE 635-640
    발표년도 2010